Saturday, April 20, 2013

The Methods An Ac Compressor Can Fail, and How To Handle It

Ac compressors usually fail because of 1 of 2 conditions: some time and hrs of operation (put on out), or abuse. You will find some failures that may occur elsewhere within the system which will result in a compressor failure, however these are less frequent unless of course the machine continues to be substantially mistreated.

Usually abuse is because of extended running with improper freon charge, or as a result of improper service on the way. This improper service may include overcharging, undercharging, setting up the incorrect starter capacitor like a alternative, getting rid of (instead of repairing/changing) the thermal limiter, inadequate oil, mixing incompatible oil types, or wrong oil, setting up the compressor on the system which had a significant burnout if you don't take proper steps to get rid of the acidity in the system, setting up the incorrect compressor (not big enough) for that system, or setting up a brand new compressor on the system which had another failure which was never identified.

The compressor can fail in just a number of various ways. It may fail open, fail shorted, notice a bearing failure, or perhaps a piston failure (throw a fishing rod), or notice a valve failure. That's virtually the whole list.

Whenever a compressor fails open, a wire within the compressor breaks. This really is unserviceable and also the symptom would be that the compressor doesn't run, although it may hum. When the compressor fails open, and following a steps here doesn't repair it, then your system might be a great candidate for any new compressor. This failure causes no further failures and will not damage the relaxation from the system when the relaxation from the product is not decrepit then it might be economical to simply place a new compressor in.

Testing for any unsuccessful open compressor is simple. Pop the electrical cover the compressor off, and take away the wires and also the thermal limiter. Utilizing an ohmmeter, appraise the impedance in one terminal to a different across the 3 devices from the compressor. Also appraise the impedance towards the situation from the compressor for those three devices.

You need to read low impedance values for those terminal to terminal connections (a couple of hundred ohms or less) and you ought to have a superior impedance (several kilo-ohms or greater) for those devices towards the situation (that is ground). If the terminal to terminal connections is an extremely high impedance, you've got a unsuccessful open compressor. In unusual cases, a unsuccessful open compressor may show a minimal impedance to ground in one terminal (which is among the devices connected using the unsuccessful open). Within this situation, the damaged wire has moved and it is getting in touch with the situation. This problem - quite rare although not impossible - might cause a breaker to trip and could cause a misdiagnosis of unsuccessful short. Be cautious here do an acidity test from the items in the lines before determining what direction to go with repair.

Whenever a compressor fails short, ultimately that insulation around the wires has worn out or shed or damaged within the compressor. This enables a wire on the motor winding to the touch something it shouldn't touch - most generally itself a turn or two further along around the motor winding. This produces a "shorted winding" that will steer clear of the compressor immediately and make it warm up and burn internally.

Bad bearings may cause a unsuccessful short. Either the rotor wobbles enough to make contact with the stator, leading to insulation damage that shorts the rotor with the idea to ground in order to the stator, or finish bearing put on makes it possible for the stator to change lower with time until it starts to rub from the stator finishes or even the housing.

Usually when one of these simple shorts occur, it's not immediately a tough short - and therefore initially the contact is intermittent and is inconsistent. Each time rapid happens, the compressor torque drops dramatically, the compressor may shudder a little noticeably consequently, which shudder shakes the winding enough to split up rapid. As the short is within place, the present with the shorted winding shoots up and lots of warmth is created. Also, normally the short will blow some sparks - which produces acidity within the ac system by rotting the freon into a combination of muriatic and hydrofluoric acidity.

With time (possibly a few days, usually less) the shuddering and also the causing and also the warmth and also the acidity cause insulation to fail quickly around the winding. Ultimately, the winding manages to lose enough insulation that within the compressor generally is burning. This can only continue for any couple of minutes but for the reason that time the compressor destroys itself and fills the machine with acidity. Then your compressor stops. It might in those days melt a wire loose and short towards the housing (which could trip your home primary breaker) or it might not. When the initial reason for the failure was bad bearings leading to the rotor to rub, then usually when the one thing finally dies it will likely be shorted towards the housing.

Whether it shorts towards the housing, it'll blow fuses and/or breakers as well as your ohmmeter can have a really low impedance from a number of windings to ground. If it doesn't short towards the housing, it will just stop. You'll still establish the kind of failure utilizing an ohmmeter.

You can't directly identify a unsuccessful short by having an ohmmeter unless of course it shorts towards the housing - a shorted winding will not appear by having an ohmmeter although it would by having an inductance meter (but that has certainly one of individuals?) Rather, you need to infer the unsuccessful short. You need to do this by creating the the ohmmeter gives normal blood pressure measurements, the starter capacitor is nice, energy is coming in the compressor, As well as an acidity test from the freon shows acidity present.

Having a unsuccessful short, just quit. Change everything, such as the lines if at all possible. It's not worth fixing it is filled with acidity and for that reason is junk. Further, a unsuccessful short might have been initially caused by a few other failure within the system that triggered a compressor overload by changing the entire system additionally you will eliminate that potential other problem.

Less generally, a compressor have a bearing failure, piston failure or perhaps a valve failure. These mechanical failures usually just signal put on out but tend to signal abuse (low lubricant levels, thermal limiter removed so compressor gets too hot, chronic low freon condition because of not-fixed leaks). More rarely, they are able to signal another failure within the system like a curing valve problem or perhaps an expansion valve problem that ends up letting liquid freon enter into the suction side from the compressor.

If your bearing fails, usually you will be aware since the compressor will seem just like a motor having a bad bearing, or it'll secure and won't run. Within the worst situation, the rotor will wobble, the windings will rub around the stator, and you'll find yourself having a unsuccessful short.

When the compressor locks up robotically and does not run, you will be aware since it will buzz very noisally for any couple of seconds and could shudder (as with every delayed motor) before the thermal limiter cuts them back. Whenever you do your electrical inspections, you'll find no proof of unsuccessful open or unsuccessful short. The acidity test can have no acidity. Within this situation, you could try a tough-start package but when the compressor has unsuccessful robotically hard-start package will not obtain the compressor to begin. Within this situation, changing the compressor is a great plan as long as the relaxation from the product is not decrepit. After changing the compressor, you have to carefully evaluate the performance from the entire system to find out if the compressor problem was caused by another thing.

Rarely, the compressor are experiencing a valve failure. Within this situation, it'll either wallow in it and appearance to operate happily and can pump no fluid (valve will not close), or it'll secure because of an lack of ability to maneuver the fluid from the compression chamber (valve will not open). If it's running happily, then after you have revealed that there's indeed lots of freon within the system, but there is nothing moving, then you've no choice but to alter the compressor. Again, a method having a compressor which has were built with a valve failure is a great candidate for any new compressor.

Now, when the compressor is robotically secured it may be due to a few things. When the compressor is on the electric, make certain the curing valve isn't stuck midway. Also make certain the development valve is working if it's blocked it may lock the compressor. Also make certain the filter isn't clogged. I remember when i saw a method which had a locked compressor because of liquid lock. Some idiot had "maintained" the machine with the addition of freon, and adding freon, and adding freon until the one thing was completely filled with liquid. Believe me that doesn't work.

Should diagnosis show a clogged filter, then this ought to be taken as positive proof of some failure within the system Apart from a compressor failure. Typically, it will likely be metal fragments from the compressor that clogs the filter. This could only happen if something is leading to the compressor to put on very quickly, especially in the pistons, the rings, the bores, and also the bearings. Either the compressor has greatly inadequate lube OR (and much more generally) liquid freon gets in to the compressor around the suction line. This behavior should be stopped. Consider the expansion valve and also at the curing valve (for any electric).

Frequently a classic system encounters enough mechanical put on internally that it's "worn in" and requires more torque to begin from the system load than could be shipped. This technique will seem much like one having a locked bearing the compressor will buzz noisally for any couple of seconds then your thermal limiter will kill it. From time to time, this technique will begin up should you whack the compressor having a rubber mallet even though it is buzzing. This type of system is a great candidate for any hard-start package. This package stores energy and, once the compressor is told to begin, dumps extra current in to the compressor for any second approximately. This overloads the compressor, but gives additional torque for a short while and it is frequently enough to create that compressor run again. I've had hard-start kits produce an additional 8 or nine years in certain old models that otherwise I could have been changing. On the other hand, I've had them give merely a couple of several weeks. It's your call, but thinking about how cheap a tough-start package is, it's really worth trying once the signs and symptoms are as referred to.

Which, the bottom line is, is exactly what may happen to an ac compressor and you skill about this.

No comments:

Post a Comment